- CH2
- CH(D)2, JIS Hydraulic Cylinder, Double Acting, Single Rod
CH(D)2, JIS Hydraulic Cylinder, Double Acting, Single Rod
CH2 double acting hydraulic cylinders conform to JIS B 8367 specifications. Surge pressure generated when running into the cushion has been reduced by 30% or more compared to the CH series, due to the CH2's cushion seal system. Separate construction of the rod cover simplifies maintenance. Available in bore sizes 32mm to 100mm. All series types are available with auto switch capability with the exception of the steel tube type.
How to order
CH2 H BB 50 100
CH D2 H BB 50 100 M9BW
Bore size
32
40
50
32 mm
40 mm
50 mm
63
80
100
63 mm
80 mm
100 mm
With auto switch
(built-in magnet)
Tube material
Aluminum alloy
Stainless steel
Stainless steel
Nominal pressure
3.5 MPa
7 MPa
14 MPa
Symbol
E
F
H
Series type
Tubing material
Aluminum alloy
Stainless steel
Steel
Stainless steel
Nominal pressure
3.5 MPa
7 MPa
14 MPa
14 MPa
Symbol
E
F
G
H
Series type
2 pcs.
1 pc.
3 pcs.
“n” pcs.
Nil
S
3
n
Number of auto switches
Rod size series
B
C
B-series rod size
C-series rod size
Cylinder stroke (mm)
Without auto switch
Nil
Auto switch type
Port and cushion
valve positions
∗ Refer to page 359.
∗ ø32 is for B-series rod
size only.
Made to Order
specifications
For details, refer to page 359.
∗ Select applicable auto switches
from the table below.
∗ Solid state auto switches marked “” are produced upon receipt of order.
∗∗ Auto switch models D-A9 and D-APV cannot be mounted on CHD2E,
CHD2H of all bore sizes and CHD2Fø32.
Applicable Auto Switches/Refer to pages 431 to 490 for further details on each auto switch.
Type
Electrical
entry
Pre-wired
connector
Indicator
light
3-wire (NPN equiv.)
2-wire
Load voltage Auto switch model
—
100 V
100 V or less
100 V, 200 V
200 V or less
—
100 V, 200 V
—
ACDC
Lead wire length (m)
0.5
(Nil)
1
(M)
3
(L)
5
(Z)
Applicable
load
5 V
12 V
—
—
24 V
Yes
No
Yes
No
Yes
Yes
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
4-wire (NPN)
IC circuit
—
IC circuit
—
Reed auto switch Solid state auto switch
—
—
—
A33
A34
A44
Relay
PLC
Relay
PLC
Relay
PLC
24 V
24 V
Grommet
Grommet
DIN terminal
Grommet
Grommet
Wiring
(output)
Special function Tie-rod mount
ø40 to ø100
ø32
ø40 to ø100
ø32
Band mount
—
—
—
PLC
5 V, 12 V
12 V
5 V, 12 V
12 V
5 V, 12 V
12 V
5 V, 12 V
12 V
5 V, 12 V
M9N
M9P
M9B
M9NW
M9PW
M9BW
M9NA
∗
1
M9PA
∗
1
M9BA
∗
1
A96
∗∗
A93
∗∗
A90
∗∗
—
—
—
—
—
—
—
—
—
—
—
—
F59
F5P
J59
—
—
F59W
F5PW
J59W
F5BA
∗
1
F59F
A54
A64
—
—
—
A59W
—
G59
—
G5P
—
K59
—
G59W
—
G5PW
—
K59W
—
—
—
G5BA
∗
1
G59F
—
—
—
B54
B64
B59W
G39
K39
—
—
None
IC circuit
—
IC circuit
—
IC circuit
—
IC circuit
—
IC circuit
Basic type
Transaxial foot type
Axial foot type
Rod rectangular flange type
Head rectangular flange type
Rod rectangular flange type
Head rectangular flange
type
Rod square flange type
Head square flange type
Single clevis type
Double clevis type
Center trunnion type
B
LA
LB
FA
FB
FY
FZ
FC
FD
CA
CB
TC
Mounting type
For
3.5 & 7
MPa
For
14 MPa
Nil
A
Nil
J
K
Nil
N
R
H
Cylinder options
∗ Indicate in alphabetical order.
Rod boot
Rod end
nut
Without rod end nut
With rod end nut
Without rod boot
Nylon tarpaulin
Neoprene cloth
With double-side cushion
Without cushion
With rod cushion
With head cushion
Cushion
With Auto Switch
How to Order
Refer to the standard stroke table on page 359.
Refer to page 378 for minimum stroke with auto switch.
Diagnostic indication (2-color indicator)
Diagnostic
indication
(2-color indicator)
Water resistant
(2-color indicator)
Diagnostic output (2-color indicator)
Terminal
conduit
Terminal
conduit
∗ Lead wire length symbols: 0.5 m ······ Nil (Example) M9NW
∗ Since there are applicable auto switches other than listed, refer to page 380 for details.
∗ For details about auto switches with pre-wired connector, refer to pages 474 and 475.
∗ D-A9, M9, M9W, M9A auto switches are shipped together. (not assembled). (Only the auto switch mounting bracket is pre-assembled.)
1 m ······ M (Example) M9NWM
3 m ······ L (Example) M9NWL
5 m ······ Z (Example) M9NWZ
∗1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
The water resistant type CH2F series is recommended for use in an environment which requires water resistance. Consult with SMC regarding the water resistant type CH2E, CH2G and CH2H series.
JIS Standard Hydraulic Cylinder
Double Acting/Single Rod
ø32, ø40, ø50, ø63, ø80, ø100
CH2E/CH2F/CH2G/CH2H
Series
3.5 MPa
7 MPa
14 MPa
358
Tube material
Nominal pressure (MPa)
Bore size (mm)
Auto switch mounting
Model
Action
Fluid
Nominal pressure (MPa)
Model
Piston speed
Cushion
Models
Specifications
CH2E
Aluminum alloy
3.5
Applicable
CH2E
CH2F
Stainless steel
7
Applicable
CH2G
Steel
14
—
CH2H
Stainless steel
14
Applicable
32, 40, 50, 63, 80, 100
Maximum
allowable pressure (MPa)
Minimum
operating pressure (MPa)
Ambient and
fluid temperature
Proof pressure (MPa)
CH2F
CH2G
CH2H
Double acting/Single rod
Hydraulic fluid
3.5 7 14
Head: 9
Rod: B rod 13.5
: C rod 11
Head: 18
Rod: B rod 18
: C rod 14
3.5
5.0
10.5 21
Head: 0.15
Rod: 0.2
Without auto switch: –10 to 80°C
With auto switch: –10 to 60°C
8 to 300 mm/s
Cushion seal type
Stroke length tolerance
to 100 st , 101 to 250 st , 251 to 630 st ,
631 to 1000 st , 1001 to 1800 st
+0.8
0
+1.25
0
+1.0
0
+1.4
0
+1.8
0
Note) Refer to page 214 for definitions of terms related to pressure.
32, 40, 50
63
80, 100
B
(Basic type)
LA, LB
(Foot type)
FA, FB, FC
FD, FY, FZ
(Flange type)
CA, CB
(Single clevis type)
TC
(Center trunnion type)
Standard Strokes
Port and Cushion Valve Positions
Standard strokes (mm)
Mounting
type
Position
Symbol
Nil A C D E F G H
Port: Top
Cushion valve:
Right
Port: Right
Cushion valve:
Bottom
: Piping port
∗ The cylinder's exterior dimensions represented here are as seen from the rod end of the cylinder.
: Cushion valve
Port: Left
Cushion valve:
Top
Port: Top
Cushion valve:
Left
Port: Top
Cushion valve:
Bottom
Port: Right
Cushion valve:
Top
Port: Right
Cushion valve:
Left
Port: Left
Cushion valve:
Right
Long stroke (mm)
25 to 800
25 to 800
25 to 1000
1800 (1401 or more with tie-rod reinforcing ring)
Note 2)
1800 (1501 or more with tie-rod reinforcing ring)
Note 3)
1800
Cylinder bore size (mm)
Symbol Specifications
-XA
-XC14
Note 1)
Refer to pages 230 and 231, to determine stroke limitation depending on the type of mounting brackets that will be
used. Then make yur selection. Long stroke ranges also differ depending on the type of mounting brackets.
Note 2) The long stroke range for the CH2E, CH2F, and CH2H series with flange and clevis type mounting brackets as
well as the CH2G series is up to 1400 mm.
Note 3) The long stroke range for the CH2E, CH2F, and CH2H series with flange and clevis type mounting brackets as
well as the CH2G series is up to 1500 mm.
Change of rod end shape
Change of trunnion bracket mounting position
Rod Sizes
B-series
C-series
40
22.4
18
32
18
—
50
28
22.4
63
35.5
28
80
45
35.5
100
56
45
Rod size
series
∗
Bore size
(mm)
(mm)
Accessories (Option)
∗ Based on JIS B8367.
Note) Maximum operating temperature:
Nylon tarpaulin (60°C),
Neoprene cloth (110°C)
∗ Refer to page 375 for part numbers and dimensions.
(For rod boot, refer to the dimensions.)
(Front and rear sides)
Cushion Strokes
Bore size (mm)
Effective cushion stroke
(mm)
40
16
32
16
50
17
63
16
80
20
100
23
Single knuckle, Double knuckle, Lock
nut, Knuckle pin, Rod boot (Nylon
tarpulin, Neoprene cloth)
Note)
∗ Consult with SMC.
Hydraulic Fluid Compatibility
Standard mineral hydraulic fluid
W/O hydraulic fluid
O/W hydraulic fluid
Water/Glycol hydraulic fluid
Phosphate hydraulic fluid
Compatibility
Compatible
Compatible
Compatible
∗
Not compatible
Hydraulic fluid
Made to order specifications
(For details, refer to page 382)
CH2E/CH2F/CH2G/CH2H Series
JIS Standard Hydraulic Cylinder
Double Acting/Single Rod
359
CHQ
CHK
CHN
CHM
CHS
CH2
CHA
D-
Related
Products
CH2
A
Related Products
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery